General info: Looking to get current attic ventilator fan replaced. The attic is about 1400 sq. ft. Current attic ventilation fan is a foot from the ridge of the roof. Live in USA.

Handyman wants: To install two 1500 CFM fans. Two 120 volt 20amp dedicated circuits, one for each fan. He wants to install the second fan 4 feet away from the current fan. He stated that the attic ventilator fan would need to be replaced within 6 years.

My questions: Would two fans be better than one fan? Would I need two 120 volt circuits to run two fans? Is there an attic ventilator that has a user replaceable fan?

Thank you in advance for any help.

  • stands_while_poops@lemmy.world
    link
    fedilink
    arrow-up
    0
    ·
    6 months ago

    3000CFM is probably too much. Your exhaust needs to match your soffit intake in terms of how much air they move. You can’t just exhaust air without replacing that air. Find a roofing contractor and not a handy man.